Allied Medical Limited
Allied Medical Limited
Udyog Vihar, Gurgaon, Haryana
SEND SMS
SEND EMAIL

Patient Monitors

With our wide experience and knowledge in this industry, we are able to provide a durable range of Patient Monitors. The range we offer comprises Meditec Pulse Oximeter and Meditec Multipara Monitors. Designed with utmost precision under the able guidance of experienced professionals at vendors’ manufacturing unit, these are in adherence with medical industry norms. Excellent reading display, high tensile strength, compact design, dimensional accuracy and longer service life are some of the salient features that make our offered product highly popular among clients.

Multipara Monitors

Multipara Monitors
  • Multipara Monitors
Ask For Price

Product Details:

BrandMeditec Pisces
Model M-700
ApplicationIndustrial Use

Features:
  • The choice of 10.4”/12.1”/15”/17” TFT color display provides superior flexibility for different clinical applications
  • Accurate monitoring of ECG, SPO2, NIBP, TEMP, RESP, HR, PR and optional IBP, EtCo2, CO, Agent Monitoring
  • Pacemaker detection,electrosurgical interference proof
  • Defibrillation protection and defibrillation synchronization
  • OxyCRG available to judge the respiration and circular function for neonates
  • 120 hours graphic and tabular trends of all parameters
  • USB ports and SD card slot to ensure data storage/function upgrades
  • Select from either Sidestream, or Mainstream EtCO2 technology to obtain fast, simple, and accurate CO2 results
  • Multi-gas module measures 5 anaesthetic agents, EtCO2, N2O and O2. It also provides automatic agent identification and display.
  • Nurse call function and Bi-directional communication with Central

Display:
  • Various working interface selectable: Standard Monitoring Display, Large Font Intensive Care Display, Trend Graph/ Monitoring Co-Display, Bed to Bed view Display (optional), OxyCRG Dynamic View Display, Drug Dose Calculation Interface
  • Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

ECG:
  • Lead Mode: 3 Leads (R, L, F or RA, LA, LL), 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
  • Waveform: 7 waveforms display on screen
  • 4 selectable plus: 0.25, 0.5, 1, 2 cm/mV
  • PACE detection Detection leads: 7 selectable leads: I, II, III, AVR, AVL, AVF, V
  • Defibrillation energy distributary Input voltage range ±8mV, polarized voltage: ±500mV
  • CMRR Diagnosis: >100 dB (no 50Hz/60Hz software wave trap)
  • Monitor: >110 dB (has 50Hz/60Hz software wave trap)
  • Surgery: >100dB (50Hz/60Hz software wave trap)
  • System noise: <30μV p-p (RTI)
  • HR Measuring and Alarm Range
  • Adult/Ped: 15 bpm – 300bpm
  • Neo: 15 bpm – 350bpm
  • Accuracy: ±1% or ±1bpm, which great
  • Resolution: 1 bpm
  • Sensitivity: > 200 μV P-P
  • Differential Input Impedance: ≥ 5 MΩ
  • Electrode offset potential: 300mVd.c. – 600mVd.c.
  • Patient leakage current: < 10 uA
  • ECG Signal Range: 6 mV (Vp-p).
  • ST Segment Monitoring Range  Measure and Alarm: -2.0 – +2.0 mV

Respiration:
  • Method: Impedance between R-F (RA-LL), R-L (RA-LA)

Respiration Rate Measuring and Alarm Range:
  • Adult: 0 rpm – 120 rpm Neo/Ped 0 rpm – 150 rpm
  • Resolution: 1 rpm Accuracy 2 rpm
  • Gain Selection: 0.25,0.5, 1, 2, 3, 4, 5

IBP:
  • Channel: Upto 4 channel
  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Static Pressure Measuring Range: (-)50 – +300 mmHg (up to 350 mmHg)
  • Static Pressure Accuracy: ±2% or ±1mmHg whichever is higher
  • Dynamical Pressure Measuring Range: (-)50 – +300 mmHg
  • Dynamical Pressure Accuracy: 2 % or 1mmHg which bigger
  • ART: 0 – 300 (mmHg) PA 6 – 120 (mmHg)
  • CVP/RAP/LAP/ICP: (-)10 – 40 (mmHg) P1/P2 (-)50 – 300 (mmHg
  • Resolution: 1 (mmHg) Zero range 200 mmHg

CO:
  • Method: Thermodilution Technique
  • Measuring range - CO: 0.1 – 20 L/min
  • TB: 23 – 43°C TI (-)1 – 27°C
  • Resolution - CO: 0.1 L/min TB, TI 0.1°C
  • Accuracy - CO: 5% or 0.2 L/min TB 0.1°C
  • TI: 0.1°C
  • Output parameters: CO, Hemodynamic Calculation
  • Alarm range: 23 – 43°C
Request
Callback


Additional Information:

  • Item Code: M-700
Yes! I am interested
View PDF

Modular Patient Monitor

Modular Patient Monitor
  • Modular Patient Monitor
Get Best Quote
Approx. Price: Rs 3 Lakh / Piece

Product Details:

Minimum Order Quantity01 Piece
Size L x H x D210mm x 251mm x 192 mm
Weight2.7kg (without battery)
Display7 inch, LCD Color TFT
Resolution320x240
Power Supply100-240 VAC, 50/60HZ Pmax=70VA FUSE T 1.6AL
Battery TypeLi battery
Voltage14.8 V DC
Battery Backup4 hrs

Features:
  • 7″ large high resolution colour TFT display
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Upto 4 hours working capacity with builtin rechargeable battery
  • Networking capability
  • Suitable for adult, paediatric and neonate patients

NIBP:
  • Method: Oscillometric
  • Mode: Manual, Auto, Continuous Measuring Interval in AUTO Mode 1/2/3/4/5/10/15/30/60/90/120/240/480 Min
  • Continuous: 5min, interval is 5s
  • Measuring Type: Systolic Pressure, Diastolic Pressure, Mean Pressure
  • Measuring Range: Adult Paediatric Neonatal
  • SYS (mmHg): 40-270 40-200 40-135
  • DIA (mmHg): 10-215 10-150 10-100
  • MAP (mmHg): 20-235 20-165 20-110
  • Cuff Pressure measuring Range: 0-280mmHg
  • Pressure Resolution: 1mmHg
  • Maximum mean error: 5mmHg
  • Maximum Standard deviation: 8mmHg
  • Entire Measuring Period (depend on HR/motion disturbance): 20-45s typical
  • Over-Pressure Protection: Dual Over-Pressure Protection
  • Adult: 297±3mmHg
  • Paediatric: 240±3mmHg
  • Neonatal: 145±3mmHg

ECG:
  • Lead Configuration: Standard 3-lead or 5-lead
  • 3-lead: RA, LA, LL, Lead method : I, II, III
  • 5-lead: RA, LA, LL, RL, V Lead method: I, II, III, aVR, aVL, aVF, V
  • Increase: ×250, ×500, ×1000, ×2000

Classification:
  • Anti-electroshock type: Class I equipment and internal powered equipment
  • EMC type: Class A
  • Anti-electroshock degree: SpO2 ,NIBP, BF Compliant with Safety Standards directive 93/42/EEC including amendments by directive 2007/47/EC IEC/EN 60601-1 IEC/EN 60601-1-2 ISO 9919 IEC/EN 60601-2-30 IEC 60601-2-49

Environmental:
  • Storage/Shipping/ Temp: -20 C to 70 C
  • Operating Temp: 5 C to 40 C
  • Operating Altitude: -382 m to 3012 m
  • Relative Humidity: 15% to 95% nonconsidering

SpO2:
  • Measuring Range: 0 - 100 %
  • Alarm Range: 0 - 100 %
  • Resolution: 1 %
  • Accuracy Adult (including Paediatric): ± 2 digits (70%~100% SpO2 ) Undefined (0~70% SpO2 )
  • Neonate: ±3 digits (70%~100% SpO 2 )
  • Undefined: (0~70% SpO2 )
  • Pulse Rate Measuring and Alarm range: 30 ~ 254 bpm
  • Resolution: 1 bpm
  • Accuracy: ± 3 bpm
  • Data update Period: 1s

Recorder:
  • Recorder: Optional
  • Record Width: 48 mm
  • Paper Speed: 25mm/s
Request